 | Sistema di encoder TONiC™ RSLMAl momento, questa pagina non è disponibile nella lingua scelta. È possibile visualizzare una traduzione automatica realizzata con Google Translate. Renishaw declina qualsiasi responsabilità relativa alla fornitura di tale servizio e specifica di non avere controllato la traduzione. È possibile contattarci per richiedere ulteriore assistenza.
The new RSLM stainless steel spar scale offers performance to rival fine pitch glass scales yet is available in lengths up to 10 m. RSLM offers a total accuracy (including slope and linearity) better than ±4 μm over a 5 m length – an industry first! With ±30 nm cyclic error, patented filtering optics, resolution to 1 nm and simple installation, RSLM retains all of the benefits of a 20 μm encoder yet provides the performance of a fine pitch system.
RSLM 20 µm pitch stainless steel scale
20 µm RSLM stainless steel scale is perfect for long travel applications where metrology can not be compromised.
- The robust spar scale is available in defined lengths up to 10 m.
- Total accuracy better than ±4 µm over a 5 m length.
- Thermal expansion: 10.8 µm/m/°C.
- RSLM can be coiled for simple storage and handling, yet once uncoiled behaves as a spar scale.
- Mounted using specially formulated adhesive tape or mechanical clips.
- IN-TRAC™ auto-phase optical reference mark, bi-directionally repeatable even at maximum speed (10 m/s).
- Multiple IN-TRAC reference mark positions: scale mid-point (RSLM), scale end-point (RSLE), distance coded for short travel indexing (RSLD) or regularly spaced for customer selection (RSLC)
Dual optical limits provide on-scale end-of-travel indication.
TONiC T1010 readhead & Ti interface features and benefits
Cyclic error of ±30 nm, offering ‘fine pitch’ encoder performance.
- Compact dimensions - 10.0 mm x 35.0 mm x 13.5 mm (H x L x W).
- Excellent signal stability in conditions unsuitable for most open optical encoders.
- User selectable gain control (AGC) maintains 1 Vpp analogue signal amplitude.
- Capable of operation up to 10 m/s and 70 °C.
- New! Low noise (jitter) filtering optics for improved positional stability.
- Industry standard analogue and digital outputs.
- Integral LEDs on readhead and interface for optimum set-up and system diagnosis.
- High flex UL approved cable – up to 10 m between readhead and interface.
- Fully RoHS compliant
Technical specifications
| Readhead dimensions |
10.0 mm x 35.0 mm x 13.5 mm (H x L x W) |
| Outputs (resolution) |
RS422: 5 µm, 1 µm, 0.5 µm, 0.2 µm, 0.1 µm, 50 nm, 20 nm, 10 nm, 5 nm, 1 nm
Analogue: 1Vpp
|
| Reference mark |
IN-TRAC auto-phase optical |
| Limit switches |
Customer positioned magnetic dual limits (available on linear scale only) |
| Maximum speed |
10 m/s |
| Ride height tolerance |
2.1 ±0.15 mm |
| Scale types |
RSLM stainless steel linear (also available with linear RGSZ gold tape scale, RELM Invar spar scale, and RESM and REXM rotary) |
| Vacuum compatible |
No | |